Can you direct me to the proper hi low switch for this motor?
Reply
Unfortunately the manufacturer does not offer the switch for the 2 speed 220v motors any longer. If you already have a 220 volt timer (on/off) you would need an Intermatic T106R to switch from high to low speed. If you do not have a timer currently you would need the T10604R which is a 220v on/off timer and a high/low timer.
Reply
What is the rotation for a spx1615z2ms & where should I look at the motor from the front or from the back ?
Reply
Hi Edgar, When looking at the motor from the front it should turn in a counter clockwise rotation.
Reply
Hi Patrick, The rotation looking from the front is correct counter clockwise; then what could be the cause tt is not pumping the water toward the filter ?
Reply
Hi Edgar, I would check the impeller and diffuser to make sure that they are not cracked, chipped or damaged. You may consider a tune up kit which would replace all of your o-rings, gaskets and shaft seal as if you are having an air leak then this would correct the issue. We also have a guide here on How to Troubleshoot Low Flow which should be helpful.
Reply