Model # PE153P
New Mini-PE Series Digital Controls
Intermatic’s NEW MINI-PE Series Digital Controls couple the standard features of our compact T100 Series with the convenience of digital automation. The latest innovation from Intermatic, the P1353ME allows the ability to program up to three circuits. Beyond single and two-speed pump/booster pump applications, auxiliary modes can control pumps up to 3HP as well as underwater, garden and/or fountain lighting. Countdown and override features allow cycle interruptions when pool/spa service is required. All timing and protection associated with filter pump/booster pump combos and two-speed pumps has already been integrated into the digital software. The MINI-PE Series is available in both metal and plastic enclosures and with a wired remote command, freeze probe or both. See chart below for details.
Applications:
• Single Speed Pump/Booster Pump Combos • Two-Speed Pump/Booster Pump Combos
• Water Feature Applications • Garden & Fountain Applications
• Pool & Spa Lighting • Landscape Lighting
Modes:
Mode 1 – (Aux1, Aux2, Aux3) - The time switch is a 3-circuit switch with all three switches controlling auxiliary devices.
Mode 2 – (Pump High, Pump Low, Aux3) - The time switch is a 2-circuit switch with the 1st & 2nd switch controlling a 2-speed pump. The 3rd switch is controlling any auxiliary device. All protection associated with a two speed pump is preprogrammed into this mode.
Mode 3 – (Pump, Aux2, Cleaner Pump) - The time switch is a 3-circuit switch with the 1st switch controlling a single speed pump, the 2nd switch controls any auxiliary device, and the 3rd switch operates a booster/cleaner pump. All timing & protection associated with a filter pump/cleaner pump combination is preprogrammed into this mode.
Mode 4 – (Pump High, Pump Low, Cleaner Pump) - The time switch is a 2-circuit switch with the 1st & 2nd switch controlling a 2-speed pump. The 3rd switch is controlling a booster/cleaner pump. All protection associated with a 2-speed pump and booster/cleaner pump combination is preprogrammed into this mode.
Mode 5 – (Pump L1, Pump L2, Aux3) - The time switch is 2-circuit switch with the 1st & 2nd switch controlling a 240V pump, where both L1 & L2 are required to be disconnected when the pump is turned OFF. The 3rd switch is controlling any auxiliary device.
Click Here for PE153ME Digital Mechanism Brochure
Click Here for PE153 Digital Time Clock & Accessory Brochure
Specifications:
Case – NEMA 3R rated for indoor-outdoor installation. 9-3/8" (23.8 cm) high, 5-1/2" (14.0 cm) wide, 3-5/8" (9.2 cm) deep in
beige finish. “P” suffix models are same dimensions, except made from outdoor grade plastic.
Knockouts – Combination 1/2" – 3/4" nominal knockouts, one on back and each side of case and two on bottom.
Switch Rating (each circuit) –
20 Amp Resistive, 120/240 VAC, 50/60 Hz; 20 Amp FLA @ 120 VAC, 96 Amp LRA @ 120 VAC, 50/60 Hz; 17 Amp FLA @ 240 VAC,
80 Amp LRA @ 240 VAC, 50/60 Hz; 5 Amp Tungsten, 120/240 VAC, 50/60 Hz; 5 Amp Ballast, 120/240V VAC, 50/60 Hz
Shipping Weight – 3.75 lbs
Accessories:
Click here for more Intermatic Timers
If there is a power outage will it retain the programmed cycles?
Reply
The PE153 does have a battery backup. The capacitor can hold a 4 hour charge. The programs stay locked in even if the power is out longer. You would just need to reset the time.
Reply
Can we program each separate circuit to independently turn on/off at different times of the day and for different amounts of time?
Reply
Yes, the timer can be set to run the different circuits at different times.
Reply
Can I use this timer to operate my pool pump and gas heater? And can i set the timer to run only my pump during the night and pump and heater for around 4 hours during the day?
Reply
Hi, John. Yes, you can schedule the pump only during the day and the pump and heater ant the same time. The pump and heater will have to the same voltage.
Reply