Top
Model # RAY16065
Alternate Part #'s RAY016065
Product Description
The Hi Delta® line of fan-assisted combustion units offers solid performance with low emissions, flexible control, and easy-to-understand diagnostics.
BASIC DATA
Model Number |
Full Input in BTUH |
Indoor Stack Dia. |
Bypass Options |
H-Style Bypass |
None (Field-Supplied) |
CWR |
P-992C |
990,000 |
10" |
STD |
Yes |
Yes |
P-1262C |
1,260,000 |
12" |
STD |
Yes |
Yes |
P-1532C |
1,530,000 |
12" |
STD |
Yes |
Yes |
P-1802C |
1,802,000 |
14" |
STD |
Yes |
Yes |
P-2002C |
1,999,000 |
14" |
STD |
Yes |
Yes |
P-2072C |
2,070,000 |
14" |
STD |
Yes |
Yes |
P-2342C |
2,340,000 |
16" |
STD |
Yes |
Yes |
Features:
- 83.1% efficiency
- Multiple vertical venting and sidewall venting options. No extractor required for sidewall applications up to 70ft on room air.
- All models indoor/outdoor certified
- Patented burner “security blanket” enhances staged combustion, minimizes installation/start-up issues, and protects burners from metal fatigue.
- 105ºF minimum inlet water temperature
- Cupro-nickel finned-tube heat exchanger with brass headers. AB 1953 compliant.
- VERSA IC® control package with LCD display
- Status display lights
- Cascade control of up to 8 units, no external sequencer required.
- Diagnostics center with history in English , not in codes
- Modbus RTU BMS port (RS485)
- 0-10 VDC BMS Interface (set point or direct drive)
- Ducted combustion air capable. TruSeal® CSA-Certified direct-vent available.
- Models 992C-2002C certified to SCAQMD Rule 1146.2. Meets all Low NOx regulations.
- All models except 2002C available for natural gas and propane. Model 2002C available for natural gas only.
- Certified to the ANSI Z21.56 pool heater standard.
Bypass Options:
- The standard external bypass uses an external bypass to achieve cold-water protection.
- The Cold Water Run (CWR) option provides electronic control of a variable-speed pump to continuously adjust bypass flow, achieving real-time cold-water protection.
SureRack™
The Hi-Delta SureRack™ vertical stacking system allows you to double your heating capacity without doubling the overall footprint. The easy to assemble SureRack system comes disassembled for easy transportation and mobility at the jobsite. The location of the vent connection on the Hi-Delta is modular to allow the boilers to be stacked vertically with no offset. The powder coated, heavy duty construction is ideal for indoor or outdoor installations.