?     Asked on 5/20/2015by Chuck

My heater turns on and the gas ignites but it only runs for about 20 seconds or so and shuts the gas off, but the blower remains on .and it will ignite again in about 3 minutes or so. What could the problem be.
 Reply

A  Answered on 5/21/2015 by InyoPools Product Specialist Joe S.

Hi Chuck Attached is the user Installation, Opertion and serive manual for this heater
 Reply


?     Asked on 6/16/2015by James Holzman

My heater fires up, heats for five seconds, and goes back to prefire condition. The blower never changes speed. What voltages should I have on the low and high speed contacts. I have 115 on the low and 83 on the high.
 Reply

A  Answered on 6/18/2015 by InyoPools Product Specialist Lennox H.

James, That info is not available in the Hayward Heaters Above Ground Manual, you will have to call Hayward Tech Support at 908.355.7995 for assistance.
 Reply


?     Asked on 6/2/2018by Inyo Visitor

Hayward h100id pool heater fan wont go on great water pressure clean filter
 Reply

A  Answered on 6/3/2018 by InyoPools Product Specialist Lennox H.

Hi. It could be several things including a bad Blower Switch. Use the wiring diagram located in the Hayward Heaters Above Ground Manual to do a diagnose the issue.