Part # 6200-109B
Manufacturer Code W0036901
Generator, Pilot/thermocouple (w0036901)
This thermocouple WI
ll, work with lars lite 2 unit
Reply
This Pilot/thermocouple Generator (W0036901) will work in the Teledyne/Jandy Laars Lite and Lite 2 Heater
Reply
Hello I have a Laars Teledyne heater and my thermocouple looks like it is Deteriorate it it is not keeping pilot lit will this replacement work on This model?
Reply
Rob, The Pilot/Thermocouple Generator (W0036901) will work on the selected heaters, Teledyne/Jandy Laars Lite and Lite 2, Teledyne Laars/Jandy Series 2 ESG and Teledyne Laars Series 1 Millivolt Heaters. If you do not have one of these units, you can Zodiac at 1.800.822.7933 to find out if this part will work on your unit.
Reply
Laars 2 pool heater The pilot goes out no matter how long I hold down button.
replaced valve last year, what can the problem be?
Reply
Bob, To troubleshoot the issue, please call Zodiac. They will be able to walk you through diagnosing the issue. You can reach them at 800-822-7933.
Reply
What milli voltage should my pilot generator be producing. I am getting a reading of 239 and I am wandering if that is not enough to open the gas valve.
Reply
Hi, Greg. This thermocouple should be generating 500-750 millivolts. A minimum of 500 MV is required to open the gas valve.
Reply
The Most Recent Reviews
(5 out of 5 stars)
Reviewed By: Inyo Customer ()
perfect fit
Was this review helpful to you?