My control unit is no longer producing chlorine all LEDs are off however the display is still working. what are the specs for the secondary voltage lead taps so I can figure out if the transformer is bad or not
Reply
Based off the information in the Hayward AquaRite Diagnostics Manual the transformer should register 2.0-2.9 Ohms.
Reply
My power light is off but my displays still are working. I have replaced the PCB board but that did not fix the issue Is it possible the transformer is bad and needs replacing on my Aqua Rite automatic chlorinator??
Reply
Hi Paul, I would recommend having some out to inspect the panel or use the AquaRite Troubleshooting Guide to find out what is causing the issue.
Reply
What are signs that the transformer is failing?
Reply
Hi Tony, The transformer is not going to slowly fail it will either put out the correct voltage or not. On page 10 of the Aqua-Rite Troubleshooting Guide provides you with info on testing the transformer.
Reply
The power is not coming on we show after pushing Diaognostic button 2 times power is only 7-14 can this be a bad transformer, power into was checked is 110v
Reply
Hi Gil, Here is a really good AquaRite Troubleshooting Manual I would follow the steps outlined in the manual. This isn't the normal useless troubleshooting guide, it actually gives great flow charts to isolate the problem.
Reply
How do I know if my transformer is bad?
Reply
Hi, Mark. You can use the AquaRite Troubleshooting Manual to test the transformer.
Reply
Less than 1 hr
Screwdriver, Pliers
I decided after 18 years that it was time to replace all the parts in the AquaRite Panel.
1 - I shut off the power to the system
2 - I removed the Metal Panel
3 - I removed the Display Board
4 - I disconnectd the Electrical to the Main Board
5 - I removed all the wires from the Transformer to the Main Board
6 - I removed the Main Board
7 - I removed the Transformer
8 - I Installed the New Transformer
9 - I reinstalled a New Main Board
10 - I reattached all the wires to the Board and 2 other locations as described in the instructions provided
11 - I reattached the electrical wires
12 - I reinstalled a New Display Board.
13 - I plugged the Flow Meter Line to the bottom of the Main Board
14 - I plugged in the Salt Cell
15 - I replaced the front panel to the AquaRite Box
16 - I turned on the Power to the System
17 - I turned on the pump
18 - I checked to make sure the correct Salt Cell was noted in diagnostics.
19. All runs fine now