Part # 6223-177
Manufacturer Code FDXLIGN1930
Dimensions 10.5" L x 3" W x 2.75" D
Your Source for Swimming Pool & Spa Parts - INYOpools.com
What is the resistance reading on a good unit?
Reply
Hi Robert, The tester should read anywhere between 50 and 400 ohms of resistance if the igniter is still in working condition. If the tester fails to register any resistance, the igniter has failed and must be replaced.Ignitor Uhsln (fdxlign1930)
Reply
I've seen many places about the resistance being between 50-100 ohms. Mine is reading 16 ohms. It glows red during the light sequence. Should I assume it's just not getting hot enough?
Reply
Hi, Kenneth G. When testing this igniter, you must unplug the igniter from the board. The resistance should be 10.9-19.7 ohms at 77°F.
Reply
Will this be compatible with Hayward H400Id series propane heater? also, would you have a 3 way on/off switch (spa/off/pool)? Thank you!
Reply
Hi, Cindy. This Ignitor - FDXLIGN1930 is not compatible with the H400ID model. In order to locate the correct ignitor, I will need to know the operating voltage of your unit. Additional info on the switch will also be required.
Reply
It is hooked to a 15 amp breaker with a 220 line with an outside disconnect.
Reply
Cindy, The Igniter, 230V - IDXLIGN1930 or Igniter, Silicon Nitride - IDXL2IGN1930 (After 09/04) are your options based on when your unit was manufactured.
Reply
Hi there, Hopefully this information will help and hopefully I can get parts so that my pool can be heated once again! As you know, it is a Hayward, Model H400IDP1, Serial Number 00C18318. There is a date of 2001. The label inside is in English and French, if that matters. Also need a 3 way on/off switch (i.e. "Spa, Off, Pool". And I wonder if the "eye" that supposed to see the flame could be faulty?? Thank you so much!! Cindy
Reply
Cindy, Please provide pictures of your unit. Based on your model #, you will need the Ignitor 230V - IDXLIGN1930. That unit does not use a 3-Way Switch.
Reply
Hi, pics are attached as requested. I hope I took ones that will help. I have others, but could only upload this many at once. If not, please let me know. Thank you so much!
Hi. I ordered the correct ignitor and have received it. Thanks for all your help. However, since you have the pictures, what should I do about a 3 way switch and also the "flame indicator"?
Reply
Cynthia, The replacement switch is P/N CHXTSW1931. Your unit does not have a separate flame sensor, it part of the ignitor.
Reply
Hi, I received the replacement igniter and it looks nothing like the one that's on it. Pic attached of existing part. Does it look familiar to you?
Cynthia, The H-Series Ignitor Assembly - HAXIGN1931 is the correct one for your unit.
Reply
Thanks so much. That is the right ignitor. Can you also search to see if you have the ignitor control module for this part (the brass terminal is loose)? I do not have a good connection with the original module that is on the heater. Can you provide part number?
Reply
The Most Recent Reviews
(4 out of 5 stars)
Reviewed By: Inyo Customer ()
It worked
Was this review helpful to you?
(5 out of 5 stars) Easy replacement
Reviewed By: JOHN S. from Discovery Bay, CA ()
Easy to find and easy to replace! Heater is back up and running again.
Was this review helpful to you?
(5 out of 5 stars) IGNITER
Reviewed By: SQNJ from MILLBURN,NJ ()
Pros: EASY TO INSTALL
Cons: EXPENSIVE FOR AN IGNITER
GOOD REPLACEMENT PART, EASY TO INSTALL, EXPENSIVE PART CONSIDERING IT'S ONLY $2.00 WORTH OF COPONENTS
Was this review helpful to you?