$174.21

Qty:

By Zodiac


Details

Top

Part # 6204-218

Manufacturer Code R0457500

Alternate Part #'s R0457500, 47-295-1181, JDYR0457500, JNDR0457500

Product Description

Your Source for Swimming Pool & Spa Parts - INYOpools.com

Top

?     Asked on 5/26/2016by Mel

What is the resistance reading for a good functioning ignitor?
 Reply

A  Answered on 5/28/2016 by InyoPools Product Specialist Lennox H.

HI Mel, According to the LXI™ Owner's Manual "With the igniter energized, there will be voltage of 102- 132 VAC between the IGN120 and IGNFS terminals on the ignition control.
 Reply


?     Asked on 6/2/2016by sam

The blower comes on, ignition takes place but a few seconds later the burner shut's off, the blower stays on, could the igniter be faulty? Thank you Sam
 Reply

A  Answered on 6/3/2016 by InyoPools Product Specialist Scott W.

Hi Sam,That's what it sounds it could be. I'd recommend call Zodiac/Jandy at 1-800-822-7933 so they can help you diagnose the problem so that you can be sure that's the part you need.
 Reply


?     Asked on 3/13/2017by BRANDON

I JUST BOUGHT A NEW IGNITOR FROM U GUYS A WEEK AGO JUST PUT IT IN WITH TWO NEW FUSE LINKS NOW THE NEW IGNITOR IS BROKEN AND THE SCREEN IS READING FUSE LINK/FIELD COULD U TELL ME WHAt causes that since i now have to pay another 130$ after a week for my jandy lxi 400
 Reply

A  Answered on 3/15/2017 by InyoPools Product Specialist Andy O.

Hello Brandon- The only information we have from the MFG in regards to a fusible link fault would be the following: 1. Verify proper fan operation. Check for restriction or blockage of flue. Reset switch after problem is corrected. 2. Vent switch fault. 2. Identify and correct loose connections or replace switch. Refer to qualified service personnel. 3. Fusible link fault 3. Identify and correct loose connections or replace fusible link. Refer to qualified service personnel.
 Reply


Top

Review Summary

 (Average 5  out of 5 stars)
1 Ratings
5 star:
 
(1)
4 star:
 
(0)
3 star:
 
(0)
2 star:
 
(0)
1 star:
 
(0)