$2,518.52
By Summit
Model # SUM3
Features |
SUM3 |
SUM4 |
SUM5 |
BTU's | 65,000 | 85,000 | 115,000 |
C.O.P Rating | 5.9 | 5.9 | 5.9 |
Thermostat | Electronic | Electronic | Electronic |
Heat Exchanger | Titanium | Titanium | Titanium |
Compressor Type | Scroll | Scroll | Scroll |
Exclusive Propeller Blade | Yes | Yes | Yes |
Soundproofing | Exclusive Design | Exclusive Design | Exclusive Design |
Defrost System | Yes | Yes | Yes |
Service Analyzer | Yes | Yes | Yes |
Compatible with external control | Yes | Yes | Yes |
Fan Speed RPM | 825 | 825 | 1075 |
Quick Connection Included | Yes | Yes | Yes |
Labor Warranty | 5 Year | 5 Year | 5 Year |
Compressor Warranty | 10 Year (Prorated) | 10 Year (Prorated) | 10 Year (Prorated) |
Heat Exchanger Warranty | Limited Lifetime | Limited Lifetime | Limited Lifetime |
Heat Range | 60°F - 104°F | 60°F - 104°F | 60°F - 104°F |
Voltage/Phase/Hz | 208-240/60/1 | 208-240/60/1 | 208-240/60/1 |
Required Breaker | 30 | 40 | 40 |
Plumbing Connections | 1 1/2" | 1 1/2" | 1 1/2" |
Water Flow | 15-80 GPM | 15-80 GPM | 15-80 GPM |
Dimnensions (in) W x L x H | 34 x 30 x 29 | 34 x 30 x 38 | 34 x 30 x 38 |
Weight (lbs) | 189 | 216 | 238 |
Summit selects only the best components available to improve its products. Striving
to offer high-quality pool heaters that are always one step ahead of the competition.
Summit's products are well-known for their outstanding reliability because all
the units manufactured are pre-tested for 30 minutes prior to delivery.
With over ten years of experience in repairs and maintenance of heat pumps and
swimming pool heaters, the Summit team has acquired the expertise and knowledge
to manufacture a unique and durable pool heating pump system under the well-known
name of Summit. Over time, the Summit research and development team came up
with the most effective pool heater mechanical components and integrated them
into a single unit of the best quality on the market. Summit selects there pool
heater components with great care, keeping in mind the objective to manufacture
top-quality pool heating systems that are above all standards in the industry.
The Summit pool heaters consist of a Copeland Scroll compressor; an electronic
service control card, and a heat exchanger with titanium fin-type tubing that
comes with a ten-year corrosion-free warranty. In addition, they each include
a lifetime maintenance-free UV-treated plastic cover to provide protection.
All the Summit heater parts and accessories are superior in quality; this ensures
each manufactured unit with maximum, leading edge technological performance
and durability.
Advantages to using a heat pump
Minimal operating cost:
Summit 3 : $ 0,16 / hour
Summit 4 : $ 0,19 / hour
Summit 5 : $ 0,23 / hour
Keeps the water at the required temperature
Clean, ecological and safe
Maintenance-free
Quiet
Easy to use
Highly precise control
Drawbacks to using a heat pump
Loss of efficiency when the temperature is below 40°F
Investment upon purchase
Approximate Sizing Guidelines IN-GROUND POOLS- Please note
these are only approximate guidlines, due to variations on every pool location.
If you have any doubts on sizing the proper unit for you pool please contact
INYO Pool Products at 1-877-372-6038
Dimensions
(Ft) |
Area
(Sq. Ft) |
Gallons |
Model |
12
X 24 |
288 |
11,900 |
SUM3 |
14
X 28 |
392 |
16,200 |
SUM3 |
16
X 32 |
512 |
21,100 |
SUM4 |
18
X 36 |
648 |
26,700 |
SUM5 |
20
X 40 |
800 |
33,000 |
SUM5 |
Dimensions
(Ft) |
Area
(Sq. Ft) |
Gallons |
Model |
15'
Round |
177 |
5,200 |
SUM3 |
18'
Round |
254 |
7,600 |
SUM3 |
21'
Round |
346 |
10,400 |
SUM3 |
24'
Round |
452 |
13,500 |
SUM3 |
27'
Round |
573 |
17,200 |
SUM4 |
12'
X 24' Oval |
288 |
8,633 |
SUM3 |
15'
X 30' Oval |
450 |
13,490 |
SUM3 |
How long should pump run on FS code (defrost)? Outside temp here is around 15 C.
Reply
This is what I could find in the owners manual " Unit currently in defrosting cycle ( the fan works but the compressor is stopped). This is normal operation when the outside temperatures are cold. " The down side is that it does not describe whar " cold " means to them. The contact number for Summit is 908-355-7995. They are now owned by Hayward. Their technicians should be able to give you the definition of " cold " .
Reply