Part # 6223-33
Manufacturer Code CZXPRS1105
Dimensions 3.5" L x 2.25" W x 2" D
PRESSURE SWITCH,ALL PSE SERIES
have hayward h100id1 its about 10 yrs old always worked fine, this yr started working fine as usual but recently it would go on as normal heat the pool for an hr then gas flames would shut off but the blower will continue to stay on, sometimes slowing down then speeding up again, i would also hear the clicking that it wants to iginte but doesnt. can you help me to narrow down what part it could be. thanks in advance
Reply
Hi Lou, The problem could be a bad Control Module or Igniter and that's just the beginning. To properly diagnose what is causing the unit to malfunction you will need to have a service tech inspect the unit.
Reply
i have a wps1930 pressure switch will work on a h100 series heater
Reply
Hi. This Pressure Switch - CZXPRS1105 will work on the following unit Hayward H-Series Above Ground Heater, Comfortzone PSE and Models PSE, 12-54. In order to confirm I will need the complete model number.
Reply
I have a swim pro ABG 100 heater, I need water pressure switch for this model. is it the CZXPRS1105 ??
Reply
Hi, Rick. Yes, this Pressure Switch - CZXPRS1105 will fit your Swim Pro ABG 100 Heater.
Reply
I have a Hayward Model H100ID1 and need to replace the Water Pressure Switch IDXWPS1930. Is this switch comparable? If not, what can I replace it with?
Reply
Hi Ray, yes this water pressure switch is compatible with the Hayward model H100ID1 heater.
Reply