As with any automatic salt chlorine generator, tune-ups are needed from time to time. Troubleshooting a Hayward Aqua Rite can be quick and simple. By following the steps listed below, the Aqua Rite can successfully be restored.
Click Here to View Hayward AquaRite Parts Listing
InyoPools Product Specialist Dennis R. Posted: 5/17/2015
not generating - First, hopefully you have a very large pool. 19 40# bags of salt is 760# which is what you would add to a 26,000 gallon pool to go from 0 ppm to 3500 ppm. If your pool is not this large, you probably have too much salt in the pool which will turn off the SCG. If you have a large pool, turn the SCG off another 24 hours and let the salt dissolve more. That's a lot of salt to dissolve.Reply
GMS Posted: 5/16/2015
My T15 is only 6 months old. New water in the pool. The salt level reads 3400. When I turn on the unit the light comes on the generation light is on for about 1 minute, then all the lights go off. I can turn the unit off wait 30 seconds turn it back on and works again for about 1 minute then turns off. HelpReply
Anonymous Posted: 5/16/2015
Just had aquarite installed. Pump ran for about 12 hours then added 19 bags salt and continued running pump. Started aquaria but check salt light and check cell light is on. The generating light is not onReply
InyoPools Product Specialist Dennis R. Posted: 5/12/2015
salt level reading wrong - Sounds like a problem with the display PCB. Give Hayward/Goldline a call at 866-772-2100 to confirm.Reply
InyoPools Product Specialist Dennis R. Posted: 5/11/2015
Rolan – Not sure which problems you are pointing to but if it’s the “power and generating lights not on” issue, I would suggest the same answer as the comment below yours; ” Sounds like you may need a new display PCB. Verify this with Hayward/Goldline before you buy a new one. Their number is 866-772-2100’.Reply
Anonymous Posted: 5/11/2015
My board will not maintain the salt content reading. When I recalibrate the salt level it reads 3300 and will generate fine till it turns off. Then it reverts back to 400. I recal the salt level it reads 3300 again till it turns off. The cell is clean. Also, this is a replacement board that I got off amazon. Very frustrating!PatO
Reply
InyoPools Product Specialist Dennis R. Posted: 5/9/2015
no power or generating lights - Sounds like you may need a new display PCB. Verify this with Hayward/Goldline before you buy a new one. Their number is 866-772-2100.Reply
Rolan Posted: 5/9/2015
I am having the same problems, however we have only had ours for 3 years.What can we do to fix this problem.
Rolan
Reply
Anonymous Posted: 5/7/2015
my display is on but the power and generating light is not on. start up the no flow light comes as it designed to do. what could be going on.Reply
InyoPools Product Specialist Dennis R. Posted: 5/7/2015
Stephen - Check to make sure the "FLOW" label on the switch is lined up with the flow of the water. See our guide on "How to Replace an Aqua Rite Flow Switch".Reply
Stephen Posted: 5/6/2015
No Flow LED is still on after replacing flow switch (which had a cut in cord). Bought switch from your company. Any help would be greatly appreciated.Reply
InyoPools Product Specialist Dennis R. Posted: 4/26/2015
LEDs on/off - Sounds like a loose connection. Recheck both ends of the power cord and the cell cable. Also check for cuts in the lines. One of your PCBs may be going bad but I would suggest calling Goldline/Hayward to be sure. Their number is 866-772-2100.Reply
Anonymous Posted: 4/25/2015
my Aqua Rite ECG power light and generating lights come on for a few seconds then go off will come back on then off again. I had the salt cell tested at the local pool store and it passed. Not technique skills BUT with power off and removed cover all components seem to be in snug and nothing visibly looks bad. Unit has been in place for 7yrs+ any suggestions would be appreciatedthanks
Robert
Reply
InyoPools Product Specialist Dennis R. Posted: 4/3/2015
Help - Sounds like a display PCB problem but I would suggest calling Goldline/Hayward to be sure. Their number is 866-772-2100.Reply
Help Posted: 4/1/2015
Having issues with the display on the goldline aquarite electronic chlorinator. The salt reading is way off. Pool place we go to says its 3000', but my display reads 30. It then says to check cell and salt level. I adjusted the cell because a rep from company said air bubbles could cause false readings. What should I do? New main board for display?Reply
InyoPools Product Specialist Dennis R. Posted: 2/20/2015
power light off - As you say, this is not normal for LED illumination, so I would question if your SCG is producing chlorine optimally. I would suggest calling Hayward at 866 772-2100 to see if you need a new PC board.Reply
Anonymous Posted: 2/15/2015
may not be a problem but my power light is not on and the chlorinating light stays on all the time even when the amperage cycles off. no other lights are on and the diagnostics all seem to be working fine.Reply
InyoPools Product Specialist Dennis R. Posted: 10/13/2014
warnertb - Generally a AquaRite SCG is wired to only monitor system operation and to set itself off if the system operation, like no water flow, is not working correctly. It does not shut down the pump motor. I don't know what the click is in your SCG especially if the unit is turned off. For possible solutions to your motor problem, see our guide on "How To Determine Why a Motor Won't Start or Shuts Off".Reply
warnertb Posted: 10/12/2014
the motor to my pump will not turn on. When I turn it on manually I hear a click in the salt generator box. I turned off the salt generator and still am getting the click. The pump motor will not run. I smell something burned in the panel of the generator. Any ideas? anyone?Reply
InyoPools Product Specialist Dennis R. Posted: 7/22/2014
happy - I would suggest calling Hayward/Goldline at 866-772-2100. They will be able to walk you through a more complete troubleshooting sequence.Reply
happy Posted: 7/21/2014
the salt display (ppm) keeps get lower from the reading from the pool store. recalibrating has not worked, cell checks out ok. down to replacing either the main board or display board. which one would give me a false reading?Reply
wachsk Posted: 7/14/2014
thank you so very much for the informationReply
InyoPools Product Specialist Dennis R. Posted: 6/29/2014
Salt reading off - You will have to recalibrate your salt level setting. It's simple. See our guide on "How To Recalibrate the Salt Level on a Hayward Aqua Rite" for instructions.Reply
Anonymous Posted: 6/28/2014
Salt reading checked at Pool store is always higher that what my read out is on my unit..Reply
InyoPools Product Specialist Dennis R. Posted: 6/2/2014
no chlorine - Recheck the issues in this troubleshooting guide. If that doesn't help, call Hayward direct at 866-772-2100.Reply
Anonymous Posted: 6/1/2014
We have a recent installation, unit is not producing chlorineReply
InyoPools Product Specialist Dennis R. Posted: 8/17/2013
"Inspect cell" LED on - Try holding down the "Diagnostic" button for 3-5 seconds to see if that will reset the light. Have a local pool store independently check your water's salt level to ensure it is within limits. Make sure the wire from the cell is plugged into the digital controller all the way. If this doesn't help, call Hayward tech services at 1-908-355-7995.Reply
Anonymous Posted: 8/17/2013
Inspect cell light continuous: cleaned cell, reset, light still on.Installed new cell: reset, light still on. Turned off power to Aqua Rite in hopes for a hard reset. Light still on.
Any help would be appreciated!
Reply
InyoPools Product Specialist Dennis R. Posted: 5/8/2013
Aqua Rite -pump issue - If you are still getting power to the Aqua Control Unit and pump when you manually turn off the timer switch, something is wrong with the timer. The timer mechanism does go bad over time. Try replacing the mechanism (the insides) of your timer. Here's a link to the timer mechanism for the most common Intermatic Timer Mechanism Only 220V. You will need to order a different mechanism if your timer is not Intermatic.Reply
Anonymous Posted: 5/7/2013
My pump still runs when the timer switch is set to off. What could that be. Last year I replaced the main board because the pump did not run. Now I have the opposite issue.Reply